TY - JOUR
T1 - Biphasic responses of the brachial artery diameter following forearm occlusion
T2 - A blunted response in the elderly
AU - Dobrosielski, Devon A.
AU - Arce, Arturo A.
AU - Allen, Jason D.
AU - Wood, Robert H.
AU - Welsch, Michael A.
PY - 2006/4/5
Y1 - 2006/4/5
N2 - Background: The purpose was to examine the temporal response of the brachial artery diameter following 5 minutes of forearm occlusion in young men. A secondary objective was to compare the main features of the temporal pattern between young and old. Methods: Sixteen young (28 ± 8 yrs) and fifteen older (85 ± 8 yrs) men underwent high-resolution ultrasonography of the brachial artery before and after five minutes of forearm occlusion. Results: Following release of the pressure cuff the brachial artery diameter exhibits a temporal biphasic response. Initially, there is a significant reduction in brachial diameter (NIL) compared to baseline (BASE), followed by a rapid increase to a PEAK at 41 sec post release. When comparing the magnitude of the decrease in diameter and the Brachial Artery Flow Mediated Dilation (BAFMD) between Young and Old, older subjects demonstrated a blunted response (Magnitude of Decrease: Young: 2.0%; Old: 0.4%, p = 0.015, and BAFMD: Young: 7.7%; Old: 2.3%, p = 0.001). Finally, a significant relationship was noted between the magnitude of decrease and BAFMD (r = -0.44, p = 0.04). Conclusion: Examination of the temporal response of the brachial artery diameter following 5 minutes of forearm occlusion reveals a biphasic pattern in all participants. Specific features of this pattern are blunted in older adults compared with younger subjects. Finally, the magnitude of the drop in diameter following forearm occlusion correlates with the magnitude of the BAFMD.
AB - Background: The purpose was to examine the temporal response of the brachial artery diameter following 5 minutes of forearm occlusion in young men. A secondary objective was to compare the main features of the temporal pattern between young and old. Methods: Sixteen young (28 ± 8 yrs) and fifteen older (85 ± 8 yrs) men underwent high-resolution ultrasonography of the brachial artery before and after five minutes of forearm occlusion. Results: Following release of the pressure cuff the brachial artery diameter exhibits a temporal biphasic response. Initially, there is a significant reduction in brachial diameter (NIL) compared to baseline (BASE), followed by a rapid increase to a PEAK at 41 sec post release. When comparing the magnitude of the decrease in diameter and the Brachial Artery Flow Mediated Dilation (BAFMD) between Young and Old, older subjects demonstrated a blunted response (Magnitude of Decrease: Young: 2.0%; Old: 0.4%, p = 0.015, and BAFMD: Young: 7.7%; Old: 2.3%, p = 0.001). Finally, a significant relationship was noted between the magnitude of decrease and BAFMD (r = -0.44, p = 0.04). Conclusion: Examination of the temporal response of the brachial artery diameter following 5 minutes of forearm occlusion reveals a biphasic pattern in all participants. Specific features of this pattern are blunted in older adults compared with younger subjects. Finally, the magnitude of the drop in diameter following forearm occlusion correlates with the magnitude of the BAFMD.
UR - http://www.scopus.com/inward/record.url?scp=33646381902&partnerID=8YFLogxK
U2 - 10.1186/1476-5918-5-4
DO - 10.1186/1476-5918-5-4
M3 - Article
AN - SCOPUS:33646381902
SN - 1476-5918
VL - 5
JO - Dynamic Medicine
JF - Dynamic Medicine
M1 - 4
ER -