N2 - Validated computational models promise a virtual platform to create optimal articular surfaces that best achieve desired implant characteristics. Today, designers can parametrically define the primary geometric features of an implant, and automatically modify design variables until stability/mobility performance objectives are best achieved. This preclinical, virtual design iteration minimizes the development cycle compared with testing physical prototypes and, by evaluating a broader scope of design concepts, likely improves the clinical performance of the final product. However, the scenario described is not without shortcomings and requires thorough understanding of the capabilities and the limitations of the models used. Although models typically represent the articular interface well, the interaction with the patient and the surgical process includes significant variability and increase in complexity. We present current modeling capabilities for the estimation of implant stability/mobility, with further suggestions for answering the difficult question of how an implant might perform throughout the population.
AB - Validated computational models promise a virtual platform to create optimal articular surfaces that best achieve desired implant characteristics. Today, designers can parametrically define the primary geometric features of an implant, and automatically modify design variables until stability/mobility performance objectives are best achieved. This preclinical, virtual design iteration minimizes the development cycle compared with testing physical prototypes and, by evaluating a broader scope of design concepts, likely improves the clinical performance of the final product. However, the scenario described is not without shortcomings and requires thorough understanding of the capabilities and the limitations of the models used. Although models typically represent the articular interface well, the interaction with the patient and the surgical process includes significant variability and increase in complexity. We present current modeling capabilities for the estimation of implant stability/mobility, with further suggestions for answering the difficult question of how an implant might perform throughout the population.
UR - http://www.scopus.com/inward/record.url?scp=85010645211&partnerID=8YFLogxK
U2 - 10.5435/JAAOS-D-16-00640
DO - 10.5435/JAAOS-D-16-00640
M3 - Article
C2 - 27997412
AN - SCOPUS:85010645211
SN - 1067-151X
VL - 25
SP - S33-S39
JO - Journal of the American Academy of Orthopaedic Surgeons
JF - Journal of the American Academy of Orthopaedic Surgeons
ER -