Measurements of vascular function using strain-gauge plethysmography: Technical considerations, standardization, and physiological findings

  • Mahmoud A. Alomari
  • , Angela Solomito
  • , Rafael Reyes
  • , Syed Muaz Khalil
  • , Robert H. Wood
  • , Michael A. Welsch

Research output: Contribution to journalArticlepeer-review

45 Scopus citations

Abstract

The main purpose of the present study was to examine the relationships between measures of fitness [estimated peak oxygen consumption (V̇O2 peak) and handgrip strength] and forearm vascular function in 55 young (22.6 ± 3.5 yr) adults. In addition, the present study considered methodological and technical aspects regarding the examination of the venous system using mercury in-Silastic strain-gauge plethysmography (MSGP). Forearm venous capacitance and outflow were examined using five different [7, 14, 21, 28, and 35 mmHg < diastolic blood pressure (DBP)] venous occlusion pressures and after a 5- and 10-min period of venous occlusion. A pressure of 7 mmHg < DBP and a period of 10 min venous occlusion produced the greatest (P < 0.05) venous capacitance and outflow, without altering arterial indexes. Reproducibility of forearm arterial and venous indexes were evaluated at rest and after 5 min of upper arm arterial occlusion at 240 mmHg on three different occasions within 10 days with the interclass correlation coefficient ranging from 0.70 and 0.94. Estimated V̇O2 peak correlated with postocclusion arterial inflow (r = 0.54, P = 0.012) and resting venous outflow (r = 0.56, P = 0.016). Finally, handgrip strength was associated with venous capacitance (r = 0.57, P = 0.007) and outflow (r = 0.67, P = 0.001). These results indicate that the examination of forearm vascular function using MSGP is reproducible. Moreover, the data show the importance of careful consideration of the selection of venous occlusion pressure and period when implementing these measures in longitudinal trials. Finally, the associations between fitness and venous measures suggest a link between venous function and exercise performance.

Original languageEnglish
Pages (from-to)H99-H107
Number of pages9
JournalAmerican Journal of Physiology - Heart and Circulatory Physiology
Volume286
Issue number1
DOIs
StatePublished - Jan 2004

Keywords

  • Blood inflow
  • Handgrip strength
  • Oxygen consumption
  • Reliability
  • Venous outflow

Fingerprint

Dive into the research topics of 'Measurements of vascular function using strain-gauge plethysmography: Technical considerations, standardization, and physiological findings'. Together they form a unique fingerprint.

Cite this