TY - JOUR
T1 - Parathion Hydrolysis Revisited: In Situ Aqueous Kinetics by 1 H NMR
T2 - In situ aqueous kinetics by 1H NMR
AU - Wanamaker, Emma C.
AU - Chingas, G. C.
AU - McDougal, Owen M.
PY - 2013/8/20
Y1 - 2013/8/20
N2 - The kinetics of parathion (PTH) decomposition into para -nitrophenolate (pNP) and O,O-diethylthiophosphate (DETP) were measured in high-pH aqueous solutions at 20 °C by proton nuclear magnetic resonance spectroscopy ( 1 H NMR). Reaction rates were determined over a 16 h observation time, in solutions with NaOD concentrations of 5.33 mM, 33.33 mM, and 100 mM, with NaCl added to fix ionicity. The pseudo-first-order rate constants for these systems were determined to be 1.9 × 10 –4 min –1 , 1.4 × 10 –3 min –1 , and 3.8 × 10 –3 min –1 respectively. The slope of the linear plot of these rates against OD – concentration yielded the second -order hydrolysis rate constant 3.90 × 10 –5 mM –1 min –1 , valid over this pH range from 10.5 to 13. The data agree with some, and contradict other, earlier work. Our fitting procedure included background levels and allowed us to not only obtain reliable kinetic results but also to measure residual pNP and DETP impurity levels.
AB - The kinetics of parathion (PTH) decomposition into para -nitrophenolate (pNP) and O,O-diethylthiophosphate (DETP) were measured in high-pH aqueous solutions at 20 °C by proton nuclear magnetic resonance spectroscopy ( 1 H NMR). Reaction rates were determined over a 16 h observation time, in solutions with NaOD concentrations of 5.33 mM, 33.33 mM, and 100 mM, with NaCl added to fix ionicity. The pseudo-first-order rate constants for these systems were determined to be 1.9 × 10 –4 min –1 , 1.4 × 10 –3 min –1 , and 3.8 × 10 –3 min –1 respectively. The slope of the linear plot of these rates against OD – concentration yielded the second -order hydrolysis rate constant 3.90 × 10 –5 mM –1 min –1 , valid over this pH range from 10.5 to 13. The data agree with some, and contradict other, earlier work. Our fitting procedure included background levels and allowed us to not only obtain reliable kinetic results but also to measure residual pNP and DETP impurity levels.
UR - https://scholarworks.boisestate.edu/chem_facpubs/84
UR - http://dx.doi.org/10.1021/es402526n
UR - http://www.scopus.com/inward/record.url?scp=84882609019&partnerID=8YFLogxK
U2 - 10.1021/es402526n
DO - 10.1021/es402526n
M3 - Article
C2 - 23855715
SN - 0013-936X
VL - 47
SP - 9267
EP - 9273
JO - Environmental Science and Technology
JF - Environmental Science and Technology
IS - 16
ER -