TY - JOUR
T1 - Subject-specific modeling of muscle force and knee contact in total knee arthroplasty
AU - Navacchia, Alessandro
AU - Rullkoetter, Paul J.
AU - Schütz, Pascal
AU - List, Renate B.
AU - Fitzpatrick, Clare K.
AU - Shelburne, Kevin B.
N1 - Publisher Copyright:
© 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
PY - 2016/9/1
Y1 - 2016/9/1
N2 - Understanding the mechanical loading environment and resulting joint mechanics for activities of daily living in total knee arthroplasty is essential to continuous improvement in implant design. Although survivorship of these devices is good, a substantial number of patients report dissatisfaction with the outcome of their procedure. Knowledge of in vivo kinematics and joint loading will enable improvement in preclinical assessment and refinement of implant geometry. The purpose of this investigation was to describe the mechanics of total knee arthroplasty during a variety of activities of daily living (gait, walking down stairs, and chair rise/sit). Estimates of muscle forces, tibial contact load, location, and pressure distribution was performed through a combination of mobile fluoroscopy data collection, musculoskeletal modeling, and finite element simulation. For the activities evaluated, joint compressive load was greatest during walking down stairs; however, the highest contact pressure occurred during chair rise/sit. The joint contact moment in the frontal plane was mainly varus for gait and walking down stairs, while it was valgus during chair rise/sit. Excursion of the center of pressure on the tibial component was similar during each activity and between the medial and lateral sides. The main determinants of center of pressure location were internal–external rotation, joint load, and tibial insert conformity.
AB - Understanding the mechanical loading environment and resulting joint mechanics for activities of daily living in total knee arthroplasty is essential to continuous improvement in implant design. Although survivorship of these devices is good, a substantial number of patients report dissatisfaction with the outcome of their procedure. Knowledge of in vivo kinematics and joint loading will enable improvement in preclinical assessment and refinement of implant geometry. The purpose of this investigation was to describe the mechanics of total knee arthroplasty during a variety of activities of daily living (gait, walking down stairs, and chair rise/sit). Estimates of muscle forces, tibial contact load, location, and pressure distribution was performed through a combination of mobile fluoroscopy data collection, musculoskeletal modeling, and finite element simulation. For the activities evaluated, joint compressive load was greatest during walking down stairs; however, the highest contact pressure occurred during chair rise/sit. The joint contact moment in the frontal plane was mainly varus for gait and walking down stairs, while it was valgus during chair rise/sit. Excursion of the center of pressure on the tibial component was similar during each activity and between the medial and lateral sides. The main determinants of center of pressure location were internal–external rotation, joint load, and tibial insert conformity.
KW - fluoroscopy
KW - knee osteoarthritis
KW - musculoskeletal modeling
KW - TKR
UR - http://www.scopus.com/inward/record.url?scp=84984656565&partnerID=8YFLogxK
UR - http://dx.doi.org/10.1002/jor.23171
U2 - 10.1002/jor.23171
DO - 10.1002/jor.23171
M3 - Article
C2 - 26792665
AN - SCOPUS:84984656565
SN - 0736-0266
VL - 34
SP - 1576
EP - 1587
JO - Journal of Orthopaedic Research
JF - Journal of Orthopaedic Research
IS - 9
ER -