TY - JOUR
T1 - Thermo-economic analysis of steady state waste heat recovery in data centers using absorption refrigeration
AU - Ebrahimi, Khosrow
AU - Jones, Gerard F.
AU - Fleischer, Amy S.
N1 - Publisher Copyright:
© 2014 Elsevier Ltd.
PY - 2015/2/1
Y1 - 2015/2/1
N2 - This paper addresses the technical and economic issues associated with waste heat recovery in data centers through the use of absorption cooling machines. The theoretical possibility of utilizing the heat dissipated by a server, or a number of servers, to power an absorption system, which in turn produces cooling for other servers in the data center, is investigated. For this purpose, a steady-state thermodynamic model is developed to perform energy balance and exergy analyses for a novel configuration of an on-chip two-phase cooling system and an absorption refrigeration system. This combination is created by replacing the condenser in the on-chip cooling circuit with the generator of an absorption refrigeration cycle. The performance of the developed model in simulating both LiBr-water and water-ammonia absorption cooling systems is examined through verification of the model results against the reference data available in the literature. The verification indicates the superiority of LiBr-water absorption system for data center/server operating conditions. Therefore, a LiBr-water absorption refrigeration system is modeled in the novel combined heat recovery system. For these systems it is shown that the traditional definition for the coefficient of performance (COP) is not appropriate to evaluate the performance and, in its place, introduce a new figure of merit. Through a sensitivity analysis, the effects of server waste heat quality, server coolant type, solution peak concentration, solution heat exchanger effectiveness, evaporator temperature, and operating pressures on the performance of the novel system are investigated. Finally, using the thermodynamic model and cost information provided by the absorption refrigeration industry, an economic analysis is carried out to calculate the payback period when this technology is used for data center waste heat recovery.
AB - This paper addresses the technical and economic issues associated with waste heat recovery in data centers through the use of absorption cooling machines. The theoretical possibility of utilizing the heat dissipated by a server, or a number of servers, to power an absorption system, which in turn produces cooling for other servers in the data center, is investigated. For this purpose, a steady-state thermodynamic model is developed to perform energy balance and exergy analyses for a novel configuration of an on-chip two-phase cooling system and an absorption refrigeration system. This combination is created by replacing the condenser in the on-chip cooling circuit with the generator of an absorption refrigeration cycle. The performance of the developed model in simulating both LiBr-water and water-ammonia absorption cooling systems is examined through verification of the model results against the reference data available in the literature. The verification indicates the superiority of LiBr-water absorption system for data center/server operating conditions. Therefore, a LiBr-water absorption refrigeration system is modeled in the novel combined heat recovery system. For these systems it is shown that the traditional definition for the coefficient of performance (COP) is not appropriate to evaluate the performance and, in its place, introduce a new figure of merit. Through a sensitivity analysis, the effects of server waste heat quality, server coolant type, solution peak concentration, solution heat exchanger effectiveness, evaporator temperature, and operating pressures on the performance of the novel system are investigated. Finally, using the thermodynamic model and cost information provided by the absorption refrigeration industry, an economic analysis is carried out to calculate the payback period when this technology is used for data center waste heat recovery.
KW - Absorption refrigeration
KW - Data center
KW - Heat recovery and reuse
KW - Thermodynamics
UR - http://www.scopus.com/inward/record.url?scp=84918822447&partnerID=8YFLogxK
U2 - 10.1016/j.apenergy.2014.10.067
DO - 10.1016/j.apenergy.2014.10.067
M3 - Article
AN - SCOPUS:84918822447
SN - 0306-2619
VL - 139
SP - 384
EP - 397
JO - Applied Energy
JF - Applied Energy
ER -